Milli | 4.4mm dia. Field of View

Micro | 900µm dia. Field of View

Meso+ | 400µm dia. Field of View

Meso | 230µm dia. Field of View

arrow&v

​The BlazeMilli is under development & currently not available for shipment.

BlazeMeso 

230µm dia. Field of View

Predominantly particles < 30µm measure change to 70µm

  • 400 nanometer Resolution

  • 133 nanometer detection

  • 7.78 pixels/µm Resolution 

AirforceTarget Meso.png

BlazeMeso+

400µm dia. Field of View 

Predominantly particles < 60µm

measure change to 130µm

  • 600 nanometer Resolution​

  • 200 nanometer Detection

  • 5 pixels/µm Resolution 

AirforceTarget Meso+.png

BlazeMicro

900µm dia. Field of View 

Predominantly particles < 330um measure change to 660µm

  • <1µm Resolution

  • 400 nanometer Detection

  • 2.15 pixels/µm Resolution

AirforceTarget Micro.png

BlazeMilli

4.4mm dia. Field of View 

Predominantly particles < 1.4mm  measure change to 2.2mm

  • <6µm Resolution

  • 4µm Detection

  • 4.6 pixels/10µm Resolution

AirforceTarget Milli.png

6.2µm

Note on Resolution Target Comparisons: It is typical for the microscope industry to utilize reference targets such as the 1951 AF Standard Target above to compare 2d resolution. For more information, please contact Blaze and/or visit: https://en.wikipedia.org/wiki/1951_USAF_resolution_test_chart

Please contact Blaze for an introduction to 3D resolution, which is a critical parameter for most PAT applications.

See our Technology page on Microscopy for further detail:

BlazeMicro PG Polarization

Enables simultaneous acquisition of multi-angle, particle generated polarized light images. See our technology page on Polarization to learn more:

BlazeMicro NO PG Polarization 

Standard dark field microscopy.

arrow&amp;v

1M Microscopy 

1M Laser Classification:  Considered non-hazardous. First generation Blaze Microscopy tools are rated 1M. Hazard increases if viewed with optical aids, including magnifiers, binoculars, or telescopes.

Meso+ Basic 1M.png

3B Microscopy 

3B laser classification: Typical Raman systems are rated Class 3B. 3B indicates immediate skin hazard from direct beam and immediate eye hazard when viewed directly. The advantage of High Power 3B Illumination for Microscopy is the ability to see fainter particles.

Meso+ Basic 3B.png
 

Detachable/Interchangeable Probe Options

BlazeMeso+ Basic.png
Detachable Probe and Cable Assembly Lab Basic.PNG
Basic Lab Threads Example.png

12/14/19 OD x 276 mm Immersible

1219mm OD x 454mm L Probe Basic Meso.png

12/19 OD x 461 mm Immersible

19mm OD x 545mm L Probe Basic Meso.png

19 OD x 461 mm Immersible

12mm OD x 41mm L Probe.png

12 OD x 41mm Immersible

arrow&amp;v
arrow&amp;v

Field of View for Second Probe

PG Polarization for Second Probe

To learn more click here

Receive customized details on your chosen configuration

If you do not know which configuration is best for you, inquire below and we will reach out for further discussion!

Thank you, your inquiry has been submitted! We will get back to you ASAP.